§ 60.5380. What standards apply to centrifugal compressor affected facilities?
196 words·~1 min read·
/us/cfr/t40/s§ 60.5380·A research copy — for the controlling text, always check the official state or federal source. Not legal advice.
You must comply with the standards in paragraphs
(a)through
(d)of this section for each centrifugal compressor affected facility. (a)(1) You must reduce VOC emissions from each centrifugal compressor wet seal fluid degassing system by 95.0 percent or greater.
(2)If you use a control device to reduce emissions, you must equip the wet seal fluid degassing system with a cover that meets the requirements of § 60.5411(b), that is connected through a closed vent system that meets the requirements of § 60.5411(a) and routed to a control device that meets the conditions specified in § 60.5412(a),
(b)and (c). As an alternative to routing the closed vent system to a control device, you may route the closed vent system to a process.
(b)You must demonstrate initial compliance with the standards that apply to centrifugal compressor affected facilities as required by § 60.5410(b).
(c)You must demonstrate continuous compliance with the standards that apply to centrifugal compressor affected facilities as required by § 60.5415(b).
(d)You must perform the required notification, recordkeeping, and reporting as required by § 60.5420. [77 FR 49542, Aug. 16, 2012, as amended at 78 FR 58436, Sept. 23, 2013]
Connections7 cite this
Cited by 7 sections · top 4
Citation graph
cites case law
§ 60.5380
What standards apply to centrifugal compressor affected facilities?
Fed. Reg.×7
Cites 0Cited by 7 across 1 source